医学
分割
磁共振成像
放射科
人工智能
回顾性队列研究
Sørensen–骰子系数
医学物理学
核医学
计算机科学
外科
图像分割
作者
Hartmut Häntze,Lina Xu,Christian Mertens,Felix J. Dorfner,Leonhard Donle,Felix Busch,Avan Kader,Sebastian Ziegelmayer,Nadine Bayerl,Nassir Navab,Daniel Rueckert,Julia A. Schnabel,Hugo J.W.L. Aerts,Daniel Truhn,Fabian Bamberg,Jakob Weiss,Christopher L. Schlett,Steffen Ringhof,Thoralf Niendorf,Tobias Pischon
出处
期刊:Radiology
[Radiological Society of North America]
日期:2025-08-06
摘要
“Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop and validate MRSegmentator, a retrospective cross-modality deep learning model for multiorgan segmentation of MRI scans. Materials and Methods This retrospective study trained MRSegmentator on 1,200 manually annotated UK Biobank Dixon MRI sequences (50 participants), 221 in-house abdominal MRI sequences (177 patients), and 1228 CT scans from the TotalSegmentator-CT dataset. A human-in-the-loop annotation workflow leveraged cross-modality transfer learning from an existing CT segmentation model to segment 40 anatomic structures. The model's performance was evaluated on 900 MRI sequences from 50 participants in the German National Cohort (NAKO), 60 MRI sequences from AMOS22 dataset, and 29 MRI sequences from TotalSegmentator-MRI. Reference standard manual annotations were used for comparison. Metrics to assess segmentation quality included Dice Similarity Coefficient (DSC). Statistical analyses included organ-and sequence-specific mean ± SD reporting and two-sided t tests for demographic effects. Results 139 participants were evaluated; demographic information was available for 70 (mean age 52.7 years ± 14.0 [SD], 36 female). Across all test datasets, MRSegmentator demonstrated high class wise DSC for well-defined organs (lungs: 0.81–0.96, heart: 0.81–0.94) and organs with anatomic variability (liver: 0.82–0.96, kidneys: 0.77–0.95). Smaller structures showed lower DSC (portal/splenic veins: 0.64–0.78, adrenal glands: 0.56–0.69). The average DSC on the external testing using NAKO data, ranged from 0.85 ± 0.08 for T2-HASTE to 0.91 ± 0.05 for in-phase sequences. The model generalized well to CT, achieving mean DSC of 0.84 ± 0.12 on AMOS CT data. Conclusion MRSegmentator accurately segmented 40 anatomic structures on MRI and generalized to CT; outperforming existing open-source tools. Published under a CC BY 4.0 license.
科研通智能强力驱动
Strongly Powered by AbleSci AI