后囊膜混浊
医学
眼科
晶状体囊
人工晶状体
胶囊
人工晶状体
镜头(地质)
验光服务
超声乳化术
光学
视力
植物
生物
物理
作者
Ana Prinz,Pia Veronika Vécsei‐Marlovits,Dietrich Sonderhof,Paul Irsigler,Oliver Findl,Birgit Weingessel
标识
DOI:10.1136/bjophthalmol-2012-301899
摘要
To compare the intensity of posterior capsular opacification (PCO) between a 1-piece and a 3-piece microincision cataract surgery intraocular lens (MICS IOL) in a prospective randomised study.80 eyes of 40 patients with age-related cataract were enrolled in this study. Each patient received a 1-piece MICS IOL (AF-1 NY-60, Hoya, Tokyo, Japan) in one eye and a 3-piece MICS IOL (AF-1 iMICS Y-60H, Tokyo, Hoya) in the other eye. At the 1-year follow-up, the patients were examined at the slit lamp, visual acuity was determined and standardised high-resolution digital retroillumination images were taken for objective quantification of regeneratory PCO using an automated image analysis software (AQUA).The mean regeneratory PCO score (1-piece IOL: 0.2, 3-piece IOL 0.3, p=0.7) and the neodymium:yttrium-aluminium-garnet laser capsulotomy rate (two cases in 3-piece IOL group; p=0.5) were comparable low for both IOLs. Capsular folds occurred significantly more often in the 3-piece IOL group (p=0.02).Modification of the MICS IOL from a 3-piece to a 1-piece haptic design caused in short term no significant change in PCO amount. Compared with the 3-piece IOL, the 1-piece IOL led to significantly less capsular folds 1 year after surgery.
科研通智能强力驱动
Strongly Powered by AbleSci AI