重量分析
泛音
托尔
材料科学
湿度
相对湿度
检出限
灵敏度(控制系统)
分析化学(期刊)
电阻抗
光电子学
电压
电气工程
气象学
化学
电子工程
物理
有机化学
色谱法
天文
工程类
热力学
谱线
作者
Eric S. Muckley,Michael Naguib,Ilia N. Ivanov
出处
期刊:Nanoscale
[Royal Society of Chemistry]
日期:2018-01-01
卷期号:10 (46): 21689-21695
被引量:82
摘要
Gravimetric, direct-current electrical, and electrical impedance sensing modes were used to measure response of high surface area 2D Ti3C2 MXene film to water vapor pressures spanning 3 orders of magnitude (20 mTorr-20 Torr). The Ti3C2 film exhibited reproducible reversible response in 0.1%-95% relative humidity (RH) range with a detection limit of <20 mTorr H2O partial pressure (<0.1% RH). DC electrical current-based sensing with 3 mV operating voltage and 0.8 pW power consumption was demonstrated. The highest normalized sensitivity was shown for gravimetric sensing modalities which scale with the overtone number, reaching highest sensitivity of about 12 Hz/% RH at the 9th crystal overtone (45 MHz oscillation).
科研通智能强力驱动
Strongly Powered by AbleSci AI