Dual-Energy CT for Detecting Painful Knee Prosthesis Loosening

医学 射线照相术 假肢 接收机工作特性 胫骨 股骨 骨科手术 假体周围 核医学 放射科 常规射线照相术 外科 关节置换术 内科学
作者
Giovanni Foti,Chiara Longo,Mirko D’Onofrio,Simone Natali,Gianluca Piovan,Eugenio Oliboni,Venanzio Iacono,Massimo Guerriero,Claudio Zorzi
出处
期刊:Radiology [Radiological Society of North America]
卷期号:306 (3) 被引量:3
标识
DOI:10.1148/radiol.211818
摘要

Background Dual-energy CT (DECT) is an alternative to radiography and single-energy CT (SECT) for detecting prosthesis-related complications. Purpose To compare the diagnostic performance of DECT, SECT, and radiography for knee prosthesis loosening, with use of surgery or imaging follow-up reference standards. Materials and Methods In this prospective single-center study from December 2018 to June 2021, participants with unilateral painful knee prostheses underwent radiographic, SECT, and DECT imaging. Five blinded readers, four radiologists, and one orthopedic surgeon evaluated the images. Prosthesis loosening was diagnosed by a periprosthetic lucent zone greater than 2 mm. The sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of each method were determined and compared with use of a multireader multicase analysis. Results There were 92 study participants (mean age ± SD, 70 years ± 9.4; 67 women) evaluated. Tibial and femoral loosening were diagnosed in 47 and 24 participants, respectively. For the tibia, mean sensitivity and specificity for arthroplasty loosening were 88% and 91%, respectively, for DECT, 73% and 78% for SECT, and 68% and 81% for radiography. For the tibia, DECT demonstrated similar diagnostic performance (AUC, 0.90) to SECT (AUC: 0.90 vs AUC: 0.87, respectively; P = .13) but was superior to radiography (AUC: 0.90 vs AUC: 0.82; P = .002). Overall diagnostic performance of DECT (AUC, 0.87) for the femur was superior to both SECT and radiography (P < .001). Conclusion Dual-energy CT had generally better diagnostic performance in detecting loosening of tibial and femoral components after total knee arthroplasty compared with single-energy CT or radiography. Clinical trial registration no. 2942 © RSNA, 2022
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
LCCCC完成签到,获得积分10
2秒前
2秒前
酷波er应助如意草丛采纳,获得10
2秒前
Zzz完成签到,获得积分10
4秒前
4秒前
5秒前
gww完成签到,获得积分10
5秒前
6秒前
Orange应助哈哈采纳,获得10
6秒前
6秒前
超级万声发布了新的文献求助20
7秒前
3399发布了新的文献求助10
7秒前
anna1992发布了新的文献求助10
7秒前
8秒前
8秒前
9秒前
可爱小铭完成签到,获得积分10
10秒前
Joyful完成签到,获得积分10
11秒前
蓝桉发布了新的文献求助10
11秒前
11秒前
兔BF发布了新的文献求助10
12秒前
如意草丛发布了新的文献求助10
12秒前
李洪杰发布了新的文献求助10
14秒前
14秒前
木子成发布了新的文献求助10
15秒前
烟花应助Dding采纳,获得10
16秒前
czyzyzy完成签到,获得积分10
17秒前
18秒前
20秒前
桥豆麻袋应助飘雪|夜兔采纳,获得10
22秒前
蓝桉完成签到,获得积分20
22秒前
曲书文完成签到,获得积分10
22秒前
学术渣渣发布了新的文献求助10
23秒前
23秒前
科研通AI5应助泡泡采纳,获得10
24秒前
24秒前
所所应助懒兰采纳,获得10
24秒前
25秒前
隐形曼青应助大开口采纳,获得10
25秒前
星辰大海应助木子成采纳,获得10
25秒前
高分求助中
Basic Discrete Mathematics 1000
Technologies supporting mass customization of apparel: A pilot project 600
Introduction to Strong Mixing Conditions Volumes 1-3 500
Tip60 complex regulates eggshell formation and oviposition in the white-backed planthopper, providing effective targets for pest control 400
A Field Guide to the Amphibians and Reptiles of Madagascar - Frank Glaw and Miguel Vences - 3rd Edition 400
China Gadabouts: New Frontiers of Humanitarian Nursing, 1941–51 400
The Healthy Socialist Life in Maoist China, 1949–1980 400
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 物理 生物化学 纳米技术 计算机科学 化学工程 内科学 复合材料 物理化学 电极 遗传学 量子力学 基因 冶金 催化作用
热门帖子
关注 科研通微信公众号,转发送积分 3799327
求助须知:如何正确求助?哪些是违规求助? 3344954
关于积分的说明 10322665
捐赠科研通 3061436
什么是DOI,文献DOI怎么找? 1680323
邀请新用户注册赠送积分活动 807007
科研通“疑难数据库(出版商)”最低求助积分说明 763453