医学
血管成形术
气球
血液透析
外科
紫杉醇
切割气球
经皮
随机对照试验
内科学
心脏病学
放射科
支架
化疗
再狭窄
作者
Geert Maleux,Edwin van der Linden,Roeland J. J. Heijboer,G Serafino,Aloys F. J. Wüst,Johan A. Dol,Karen Gabriels,Peter M. T. Pattynama
标识
DOI:10.1177/15266028231215212
摘要
PURPOSE: to assess the safety and efficacy of APERTO-Paclitaxel-coated balloon angioplasty versus standard angioplasty for the treatment of dysfunctional hemodialysis shunts and native arteriovenous fistulae. METHODS: consecutive patients with dysfunctional dialysis related to underlying efferent vein stenosis were included and randomized 1:1 to either APERTO-paclitaxel drug-coated balloon (study arm) or standard percutaneous transluminal angioplasty (control arm). Primary endpoint is time from treatment until dialysis access dysfunction according to standardized Kidney Disease Outcomes Quality Initiative (KDOQI)-guidelines and assessed by Kaplan-Meier survival curves and tested for significance with log-rank analysis. Secondary endpoints include device, technical, and clinical success of the index angioplasty procedure. RESULTS: The study included 103 patients (n=51 study-group) with a de novo (n=33) dysfunctional native arteriovenous fistula (n=79) in the forearm (n=60). The majority of included patients were male with a mean age of 69.8 years, presenting with a dysfunctioning autologous arteriovenous fistula in the forearm. Device-related complications did not occur in any of the included patients. Functional hemodialysis access without need for re-intervention at 1 year after index procedure was found in n=10 (19.6%) and n=5 (9.6%) of patients treated with, respectively, paclitaxel drug-coated balloon and percutaneous transluminal angioplasty (p=0.612). A nonsignificant benefit of paclitaxel drug-coated balloon (n=5; 25%) over percutaneous transluminal angioplasty (n=1; 11%) was found (p=0.953) in de novo lesions in autologous fistulas. CONCLUSION: APERTO-paclitaxel drug-coated balloon is a safe balloon catheter to manage dysfunctional hemodialysis access; however, longer period of adequate hemodialysis circuit functioning after endovascular index stenosis treatment, using APERTO-paclitaxel drug-coated balloon versus percutaneous transluminal angioplasty could not be demonstrated.Clinical ImpactAPERTO-paclitaxel drug-coated balloon catheter is a safe device to manage dysfunctional hemodialysis access. Compared to conventional angioplasty balloon, the APERTO drug-coated balloon will not result in longer period of adequate hemodialysis circuit functioning. A non-significant benefit of APERTO drug-coated balloon was found in de novo lesions in autologous fistulas.
科研通智能强力驱动
Strongly Powered by AbleSci AI