再沸器
戊烷
分馏塔
丁烷
变压器
蒸馏
炼油厂
核工程
化学
Fortran语言
热力学
工艺工程
机械工程
工程类
电气工程
计算机科学
有机化学
电压
物理
操作系统
催化作用
作者
W. Rivera,J. Cerezo,Rosa M. Rivero,J. Cervantes,R. Best
摘要
This paper presents the theoretical analysis of the use of single stage and double absorption heat transformers operating with the water–lithium bromide mixture coupled to a butane and pentane distillation column in a Mexican refinery. A mathematical model of the heat transformers was developed in FORTRAN and integrated as a user model to the Aspen Plus simulation code. Both components coupled to the column were modelled on steady-state conditions. The results show that it is theoretically possible to reduce the energy consumed in the reboiler between 26 and 43% by the use of single stage heat transformer at specific conditions, and between 28 and 33% with double absorption heat transformers for a wide range of operating conditions. Copyright © 2003 John Wiley & Sons, Ltd.
科研通智能强力驱动
Strongly Powered by AbleSci AI