化学
电极
钻石
硼
拉曼光谱
化学气相沉积
伏安法
检出限
生物相容性
分析化学(期刊)
化学工程
电化学
纳米技术
循环伏安法
材料科学
色谱法
物理化学
光学
物理
工程类
有机化学
作者
Simona Baluchová,Mariola Brycht,Andrew Taylor,Vincent Mortet,Jan Krůšek,Ivan Dittert,Silvia Sedlaková,Ladislav Klimša,Jaromı́r Kopeček,Karolina Schwarzová‐Pecková
标识
DOI:10.1016/j.aca.2021.338949
摘要
Novel porous boron-doped diamond (BDDporous)-based materials have attracted lots of research interest due to their enhanced detection ability and biocompatibility, favouring them for use in neuroscience. This study reports on morphological, spectral, and electrochemical characterisation of three BDDporous electrodes of different thickness given by a number of deposited layers (2, 3 and 5). These were prepared using microwave plasma-enhanced chemical vapour deposition on SiO2 nanofiber-based scaffolds. Further, the effect of number of layers and poly-l-lysine coating, commonly employed in neuron cultivation experiments, on sensing properties of the neurotransmitter dopamine in a pH 7.4 phosphate buffer media was investigated. The boron doping level of ∼2 × 1021 atoms cm−3 and increased content of non-diamond (sp2) carbon in electrodes with more layers was evaluated by Raman spectroscopy. Cyclic voltammetric experiments revealed reduced working potential windows (from 2.4 V to 2.2 V), higher double-layer capacitance values (from 405 μF cm−2 to 1060 μF cm−2), enhanced rates of electron transfer kinetics and larger effective surface areas (from 5.04 mm2 to 7.72 mm2), when the number of porous layers increases. For dopamine, a significant boost in analytical performance was recognized with increasing number of layers using square-wave voltammetry: the highest sensitivity of 574.1 μA μmol−1 L was achieved on a BDDporous electrode with five layers and dropped to 35.9 μA μmol−1 L when the number of layers decreased to two. Consequently, the lowest detection limit of 0.20 μmol L−1 was obtained on a BDDporous electrode with five layers. Moreover, on porous electrodes, enhanced selectivity for dopamine detection in the presence of ascorbic acid and uric acid was demonstrated. The application of poly-l-lysine coating on porous electrode surface resulted in a decrease in dopamine peak currents by 17% and 60% for modification times of 1 h and 15 h, respectively. Hence, both examined parameters, the number of deposited porous layers and the presence of poly-l-lysine coating, were proved to considerably affect the characteristics and performance of BDDporous electrodes.
科研通智能强力驱动
Strongly Powered by AbleSci AI