Tunneled Hemodialysis Catheter Tip Design and Risk of Catheter Dysfunction: An Australian Nationwide Cohort Study

医学 血液透析 血液透析导管 导管 队列 队列研究 重症监护医学 外科 内科学
作者
Benjamin Lazarus,Kevan R. Polkinghorne,Martin Gallagher,Sarah Coggan,Nicholas A Gray,Girish Talaulikar,Sradha Kotwal
出处
期刊:American Journal of Kidney Diseases [Elsevier]
被引量:1
标识
DOI:10.1053/j.ajkd.2023.09.021
摘要

Rationale & Objective Hemodialysis catheter dysfunction is an important problem for patients with kidney failure. The optimal design of the tunneled catheter tip is unknown. This study evaluated the association of catheter tip design with the duration of catheter function. Study Design Observational cohort study using data from the nationwide REDUCCTION trial. Setting & Participants 4,722 adults who each received hemodialysis via 1 or more tunneled central venous catheters in 37 Australian nephrology services from December 2016 to March 2020. Exposure Design of tunneled hemodialysis catheter tip, classified as symmetrical, step, or split. Outcome Time to catheter dysfunction requiring removal due to inadequate dialysis blood flow assessed by the treating clinician. Analytical Approach Mixed, 3-level accelerated failure time model, assuming a log-normal survival distribution. Secular trends, the intervention, and baseline differences in service, patient, and catheter factors were included in the adjusted model. In a sensitivity analysis, survival times and proportional hazards were compared among participants’ first tunneled catheters. Results Among the study group, 355 of 3,871 (9.2%), 262 of 1,888 (13.9%), and 38 of 455 (8.4%) tunneled catheters with symmetrical, step, and split tip designs, respectively, required removal due to dysfunction. Step tip catheters required removal for dysfunction at a rate 53% faster than symmetrical tip catheters (adjusted time ratio, 0.47 [95% CI, 0.33-0.67) and 76% faster than split tip catheters (adjusted time ratio, 0.24 [95% CI, 0.11-0.51) in the adjusted accelerated failure time models. Only symmetrical tip catheters had performance superior to step tip catheters in unadjusted and sensitivity analyses. Split tip catheters were infrequently used and had risks of dysfunction similar to symmetrical tip catheters. The cumulative incidence of other complications requiring catheter removal, routine removal, and death before removal were similar across the 3 tip designs. Limitations Tip design was not randomized. Conclusions Symmetrical and split tip catheters had a lower risk of catheter dysfunction requiring removal than step tip catheters. Funding Grants from government (Queensland Health, Safer Care Victoria, Medical Research Future Fund, National Health and Medical Research Council, Australia), academic (Monash University), and not-for-profit (ANZDATA Registry, Kidney Health Australia) sources. Trial Registration Registered at ANZCTR with study number ACTRN12616000830493. Plain-Language Summary Central venous catheters are widely used to facilitate vascular access for life-sustaining hemodialysis treatments but often fail due to blood clots or other mechanical problems that impede blood flow. A range of adaptations to the design of tunneled hemodialysis catheters have been developed, but it is unclear which designs have the greatest longevity. We analyzed data from an Australian nationwide cohort of patients who received hemodialysis via a tunneled catheter and found that catheters with a step tip design failed more quickly than those with a symmetrical tip. Split tip catheters performed well but were infrequently used and require further study. Use of symmetrical rather than step tip hemodialysis catheters may reduce mechanical failures and unnecessary procedures for patients. Hemodialysis catheter dysfunction is an important problem for patients with kidney failure. The optimal design of the tunneled catheter tip is unknown. This study evaluated the association of catheter tip design with the duration of catheter function. Observational cohort study using data from the nationwide REDUCCTION trial. 4,722 adults who each received hemodialysis via 1 or more tunneled central venous catheters in 37 Australian nephrology services from December 2016 to March 2020. Design of tunneled hemodialysis catheter tip, classified as symmetrical, step, or split. Time to catheter dysfunction requiring removal due to inadequate dialysis blood flow assessed by the treating clinician. Mixed, 3-level accelerated failure time model, assuming a log-normal survival distribution. Secular trends, the intervention, and baseline differences in service, patient, and catheter factors were included in the adjusted model. In a sensitivity analysis, survival times and proportional hazards were compared among participants’ first tunneled catheters. Among the study group, 355 of 3,871 (9.2%), 262 of 1,888 (13.9%), and 38 of 455 (8.4%) tunneled catheters with symmetrical, step, and split tip designs, respectively, required removal due to dysfunction. Step tip catheters required removal for dysfunction at a rate 53% faster than symmetrical tip catheters (adjusted time ratio, 0.47 [95% CI, 0.33-0.67) and 76% faster than split tip catheters (adjusted time ratio, 0.24 [95% CI, 0.11-0.51) in the adjusted accelerated failure time models. Only symmetrical tip catheters had performance superior to step tip catheters in unadjusted and sensitivity analyses. Split tip catheters were infrequently used and had risks of dysfunction similar to symmetrical tip catheters. The cumulative incidence of other complications requiring catheter removal, routine removal, and death before removal were similar across the 3 tip designs. Tip design was not randomized. Symmetrical and split tip catheters had a lower risk of catheter dysfunction requiring removal than step tip catheters.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
华仔应助touten采纳,获得30
2秒前
灰灰12138完成签到,获得积分10
3秒前
洁净尔风完成签到,获得积分10
5秒前
rainboo完成签到,获得积分10
5秒前
jeff完成签到,获得积分10
8秒前
9秒前
rainboo发布了新的文献求助10
9秒前
友好冷之应助科研通管家采纳,获得30
12秒前
情怀应助科研通管家采纳,获得10
12秒前
结实星星应助科研通管家采纳,获得10
12秒前
友好冷之应助科研通管家采纳,获得30
12秒前
草拟大坝应助科研通管家采纳,获得10
12秒前
结实星星应助科研通管家采纳,获得10
12秒前
12秒前
26秒前
29秒前
30秒前
31秒前
皮皮完成签到 ,获得积分10
32秒前
今后应助Faint_Dream采纳,获得10
32秒前
touten完成签到,获得积分20
35秒前
阳佟半仙发布了新的文献求助30
35秒前
Zephyr发布了新的文献求助10
36秒前
Mer_Mer完成签到,获得积分10
37秒前
37秒前
39秒前
40秒前
飞翔的丫蛋完成签到,获得积分10
41秒前
41秒前
ding应助阿喵啊阿喵采纳,获得10
41秒前
42秒前
小二郎应助HongJiang采纳,获得10
43秒前
Away发布了新的文献求助10
43秒前
43秒前
12243243发布了新的文献求助10
44秒前
鲤鱼灵寒发布了新的文献求助50
45秒前
阳佟半仙完成签到,获得积分10
45秒前
紫zi发布了新的文献求助10
45秒前
Somnus完成签到 ,获得积分10
47秒前
桃桃子发布了新的文献求助10
47秒前
高分求助中
Manual of Clinical Microbiology, 4 Volume Set (ASM Books) 13th Edition 1000
Chinese-English Translation Lexicon Version 3.0 500
Electronic Structure Calculations and Structure-Property Relationships on Aromatic Nitro Compounds 500
マンネンタケ科植物由来メロテルペノイド類の網羅的全合成/Collective Synthesis of Meroterpenoids Derived from Ganoderma Family 500
薩提亞模式團體方案對青年情侶輔導效果之研究 400
[Lambert-Eaton syndrome without calcium channel autoantibodies] 400
Statistical Procedures for the Medical Device Industry 400
热门求助领域 (近24小时)
化学 材料科学 医学 生物 有机化学 工程类 生物化学 纳米技术 物理 内科学 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 电极 光电子学 量子力学
热门帖子
关注 科研通微信公众号,转发送积分 2379982
求助须知:如何正确求助?哪些是违规求助? 2087214
关于积分的说明 5240464
捐赠科研通 1814287
什么是DOI,文献DOI怎么找? 905192
版权声明 558734
科研通“疑难数据库(出版商)”最低求助积分说明 483222