腐蚀
材料科学
介电谱
极化(电化学)
X射线光电子能谱
钛
合金
扫描电子显微镜
钛合金
质子交换膜燃料电池
电化学
阳极
冶金
化学工程
膜
复合材料
化学
电极
生物化学
物理化学
工程类
作者
Yao Huang,Yue Luo,Liang Chang,Gaoqun Zhang,Xiao Hu,Guizhi Xu,Zhanfeng Deng,Hangyin Mao,Jia Feng
出处
期刊:Journal of physics
[IOP Publishing]
日期:2023-06-01
卷期号:2529 (1): 012013-012013
被引量:3
标识
DOI:10.1088/1742-6596/2529/1/012013
摘要
Abstract Titanium Bipolar Plates (BPPs) are frequently utilized in Proton Exchange Membrane Water Electrolyzers (PEMWE) nowadays since they could endure the challenging working environment. Notably, the extreme anodic potential and acidic environment of the PEMWE are extremely critical for BPPs’ performances. In this study, we explored the corrosion behaviors of conventional titanium alloys of TA1 and Ti-6Al-4V (TC4) at simulated operating conditions. To evaluate their corrosion behaviors, potentiodynamic polarization, electrochemical impedance spectroscopy, and potentiation, polarization experiments were executed. Additionally, scanning electron microscopy (SEM) was applied to detect the morphologies before and after the electrochemical measurements. Finally, the corrosion mechanisms of TA1 and TC4 were analyzed and discussed by X-ray photoelectron spectroscopy (XPS). After 7 days of potentiostatic polarization, the corrosion current density of TA1 remained at 3×10 −8 A·cm −2 , which was nearly one order of magnitude lower than that of TC4. These experimental data confirmed that the TA1 alloy had superior corrosion resistance to the TC4 alloy during long-term running in PEMWE operating conditions.
科研通智能强力驱动
Strongly Powered by AbleSci AI