热失控
电压
电压降
核工程
材料科学
汽车工程
电气工程
结构工程
模拟
工程类
物理
电池(电)
热力学
功率(物理)
作者
Lianshan Lin,J.L. Li,Isabella M. Fishman,Loraine Torres-Castro,Yuliya Preger,Valerio De Angelis,Joshua Lamb,Xiaoqing Zhu,Srikanth Allu,H. Wang
标识
DOI:10.1016/j.est.2023.106798
摘要
Thermal runaway is one of the most important safety concerns in the deployment of Li-ion batteries. We developed a standardized single-side indentation test protocol to induce an internal short-circuit. Cell voltage, temperature, and applied compressive force are monitored as a function of time. Each cell is given an observed hazard severity (OHS in five categories) modified from the EUCAR table. Meanwhile a calculated hazard severity (CHS) is obtained solely based on temperature and voltage curves. The calculation formula considers the cell temperature, rate of temperature increase, cell capacity, state of charge (SOC), voltage drop, and voltage drop rate. Each term is assigned with an appropriate weight to scale the calculated score from 0 to100. This method was applied to >100 Li-ion batteries with various SOCs and chemistries, and their OHS and CHS were displayed against SOC. The purpose is to provide battery designers, manufacturers, and end-users a clear comparison of thermal runaway severity of different batteries.
科研通智能强力驱动
Strongly Powered by AbleSci AI