医学
心肌灌注成像
部分流量储备
冠状动脉疾病
正电子发射断层摄影术
核医学
灌注
冠状动脉血流储备
心脏宠物
胸痛
血流
狭窄
灌注扫描
放射科
心脏病学
内科学
冠状动脉造影
心肌梗塞
作者
Simon Winther,Laust Dupont Rasmussen,Salma Raghad Karim,Jelmer Westra,Jonathan Nørtoft Dahl,Jacob Hartmann Søby,Louise Nissen,Fabian Bøgild Lomstein,Morten Würtz,Jens Sundbøll,June Anita Ejlersen,Jesper Mortensen,Lars Poulsen Tolbod,Hanne Maare Søndergaard,Nicolaj Christopher Lyng Hansson,Mette Nyegaard,Rebekka Vibjerg Jensen,Michael Madsen,Evald Høj Christiansen,Lars Christian Gormsen
标识
DOI:10.1161/circimaging.124.017479
摘要
BACKGROUND: Myocardial perfusion imaging by positron emission tomography (PET) is recommended as a first-line test in stable patients with chest pain symptoms and as a selective second-line test after an abnormal coronary computed tomography angiography (CTA). It is, however, unknown whether the use of Rubidium-82 ( 82 Rb) versus [ 15 O]H 2 O ( 15 O-water) affects the diagnostic performance in coronary artery disease (CAD). The aim of this study was to compare 82 Rb-PET versus 15 O-water-PET head-to-head for diagnosing obstructive CAD. METHODS: The study included consecutive patients (n=1000) referred for CTA with symptoms suggestive of obstructive CAD. Patients with suspected stenosis based on CTA were referred for both 82 Rb-PET, 15 O-water-PET, and subsequently invasive coronary angiography (ICA), including 3-vessel fractional flow reserve and coronary flow reserve measurements. RESULTS: In total, 196/270 (73%) patients with suspected stenosis on CTA completed 82 Rb-PET, 15 O-water-PET, and ICA. Myocardial blood flow measurements from 82 Rb-PET and 15 O-water-PET correlated strongly at rest (ρ, 0.62–0.69) but only moderately during hyperemia (ρ, 0.41–0.59). Only weak correlations were demonstrated between myocardial blood flow reserve by both PET tracers compared with ICA coronary flow reserve (ρ, 0.11–0.38). Hemodynamically obstructive CAD defined as ICA fractional flow reserve ≤0.80, was identified in 86/196 (44%) patients. Using predefined cutoffs, the diagnostic accuracies of 82 Rb-PET versus 15 O-water-PET were similar (sensitivity 69% [58–78%] versus 71% [60–80%], P =0.59; specificity 85% [76–91%] versus 77% [68–85%], P =0.12). Using ICA diameter stenoses >70% as a reference, only 48/196 (24%) patients had anatomically severe CAD, and 82 Rb-PET and 15 O-water-PET sensitivities increased to >85%. CONCLUSIONS: For detection of obstructive CAD by PET myocardial perfusion imaging, 82 Rb versus 15 O-water have similar diagnostic performance. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04707859.
科研通智能强力驱动
Strongly Powered by AbleSci AI