材料科学
牙种植体
多孔性
植入
钛合金
镁合金
松质骨
合金
有限元法
生物医学工程
牙槽
钛
复合材料
牙科
冶金
结构工程
医学
外科
工程类
作者
Xuetao Zhang,Jian Mao,Yufeng Zhou,Fangqiu Ji,Xianshuai Chen
标识
DOI:10.1177/0885328220957902
摘要
In this paper, a complex porous dental implant with biodegradable magnesium alloy was designed based on selective laser melting (SLM). Finite element analysis (FEA) was used to simulate the stress distribution of dental implant and alveolar bone in two models of preliminary and later stages of implant. The stress concentration area of dental implants was found not in the porous structure, and the weak part of mechanical properties accords with the work requirements. The porous structure of dental implants can promote the function of cancellous bone in the process of conducting the stress of the dental implant, thus improving the bearing capacity of dental implants. In vitro fatigue experiments were carried out on the experimental samples produced by 3D printing. Through the cell contrast experiment, it was proved that the decomposed Mg 2+ could reach the titanium surface smoothly through the porous structure and complete the proliferation of osteoblasts.
科研通智能强力驱动
Strongly Powered by AbleSci AI