医学
核医学
灌注
图像质量
灌注扫描
放射科
断层摄影术
图像噪声
辐射剂量
超声波
肝脏灌流
体积热力学
迭代重建
计算机断层摄影术
肝病
作者
Yong Chen,Weiping Ma,Bo Ma,Xiaobin MA,Lu Chen,Yongwei Liu,Aijun Wang,Ping Chen,WANG Zhijun -
标识
DOI:10.1016/j.acra.2026.10.024
摘要
RATIONALE AND OBJECTIVES: Volume perfusion CT (VPCT) of the liver provides functional information but is associated with increased radiation exposure and often requires additional multiphasic CT acquisitions. Photon-counting CT (PCCT) may enable low-dose one-stop imaging by generating diagnostic morphological images directly from perfusion datasets. To evaluate the image quality of single-phase and fused noncontrast and contrast-enhanced images generated from photon-counting CT (PCCT)-based liver dynamic volume perfusion CT (VPCT) for liver morphologic assessment. MATERIALS AND METHODS: In this prospective study, 62 patients with liver disease underwent true noncontrast PCCT, liver VPCT, and low-dose delayed-phase imaging. Single-time-point noncontrast, arterial-phase, and portal venous-phase images were reconstructed from the VPCT dataset using virtual monoenergetic image (VMI, 40-70 keV) and Threshold 3D (T3D) reconstruction. Fused T3D images were generated from multiphase perfusion data. Image quality was evaluated using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image-quality scores. Radiation dose was recorded. RESULTS: The one-stop imaging protocol yielded a lower effective dose than the simulated conventional four-phase protocol combined with perfusion imaging (25.9 ± 6.7 mSv vs 31.9 ± 8.5 mSv, P < 0.05). Compared with true noncontrast images, fused noncontrast images showed higher SNR (8.6 ± 3.0 vs 7.0 ± 1.9) and CNR (1.5 ± 1.2 vs 1.0 ± 0.8) (P < 0.05). Although subjective image-quality scores for perfusion-derived noncontrast images were lower than those for true noncontrast images, all remained diagnostically acceptable (score ≥ 3). In the arterial phase, fused images showed the lowest image noise (7.5 ± 2.7 HU), while 40-keV VMI provided the highest CNR (70.4 ± 24.0). In the portal venous phase, fused images achieved the lowest noise (8.8 ± 2.8 HU) while maintaining relatively high CNR (10.4 ± 7.8). Except for 40-keV and 50-keV portal venous-phase images, all reconstructed arterial- and portal venous-phase images achieved diagnostically acceptable subjective scores (≥3). CONCLUSION: PCCT-based liver VPCT one-stop imaging reduces radiation exposure while providing diagnostically acceptable morphologic images. The optimal reconstruction of noncontrast and contrast-enhanced images varies by imaging phase, supporting a phase-specific image optimization strategy for liver morphologic assessment.
科研通智能强力驱动
Strongly Powered by AbleSci AI