医学
心房颤动
肺静脉
烧蚀
导管消融
超声波
核医学
心房颤动消融
左肺静脉
三维超声
放射科
算法
心脏病学
计算机科学
作者
Luigi Di Biase,Fengwei Zou,Aung Lin,Vito Grupposo,Jacopo Marazzato,Nicola Tarantino,Domenico G. Della Rocca,Sanghamitra Mohanty,Andrea Natale,Majd Al Deen Alhuarrat,Guy Haiman,David Haimovich,Richard A Matthew,Jaclyn Alcazar,Graça Costa,Roy Urman,Xiaodong Zhang
出处
期刊:Europace
[Oxford University Press]
日期:2023-07-21
卷期号:25 (9)
被引量:9
标识
DOI:10.1093/europace/euad211
摘要
Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation.In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed.DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.
科研通智能强力驱动
Strongly Powered by AbleSci AI