作者
Yujian Liu,Tao Liu,Huize Yu,Shaopeng Xu
摘要
Highlights Liquid feed concentration within the pipeline is detected using ultrasonic signal attenuation principles. A multi-scale verification system verifies the feasibility of online liquid feed concentration detection technology based on non-invasive ultrasonic transmission attenuation. The concentration model for flow conditions was established, with equation accuracy verified through online measurement, achieving a maximum concentration detection error of 4% under non-invasive conditions. Abstract. To address the problem of real-time monitoring of material concentration caused by the complex rheological properties of solid-liquid two-phase mixtures during liquid feed transportation, this study proposes a non-invasive on-line detection method based on the ultrasonic attenuation principle. In the experiments, broadband piezoelectric transducers with a center frequency of 50 kHz were used in an opposing configuration to measure the concentration of liquid feed samples (corn-wheat-soybean meal) with different water-to-solid ratios. To comprehensively verify the method's effectiveness, a series of samples with water-to-solid ratios ranging from 1:1 to 4:1 were prepared, and experiments were conducted in two modes: static calibration and in-line measurement through the pipe wall. The static calibration results demonstrated the feasibility of the ultrasonic attenuation method for liquid feed concentration detection. The in-line measurement test through the pipe wall further indicated that, although the fluctuation in attenuation coefficient due to concentration changes was smaller than in the static calibration test, the trend remained consistent with the static calibration. Moreover, the acoustic directional anisotropy, which was caused by particle sedimentation under gravity in the static state, was significantly reduced during flow, with the directional difference reduced to 0.08% to 0.12%. Based on the experimental data, a quadratic polynomial regression model was developed using MATLAB to correlate liquid feed concentration with the ultrasonic attenuation coefficient. The model’s accuracy was validated using online measurement data. Verification results demonstrate that the model effectively predicts liquid feed concentration within the pipeline, with a maximum absolute error not exceeding ±4%. In summary, this study confirms the feasibility of a non-invasive detection method based on ultrasonic attenuation and demonstrates its capability for effective online monitoring of liquid feed concentration during pipeline transport. Keywords: Attenuation coefficient, Concentration prediction model, Material concentration, Non-invasive, Ultrasonic attenuation.
科研通智能强力驱动
Strongly Powered by AbleSci AI