逆变器
可靠性(半导体)
共模信号
电压
调速驱动器
感应电动机
工程类
汽车工程
直线(几何图形)
状态监测
可靠性工程
局部放电
断层(地质)
电气工程
电子工程
功率(物理)
几何学
数学
模拟信号
地震学
地质学
物理
数字信号处理
量子力学
作者
Muhammad Faizan Shaikh,Hyeonjun Lee,Byambasuren Battulga,Sang Bin Lee,G.C. Stone
标识
DOI:10.1109/tia.2023.3307344
摘要
Recently, the number of electrical machines operated via inverters has significantly increased. Multiple works have pointed out that insulation aging occurs faster for inverter-fed machines due to voltage overshoots and uneven voltage distribution caused by high dV/dt switching at several kHz. This necessitates better insulation monitoring methods so that deteriorating insulation quality can be detected, before machines fail and the industrial process is interrupted. A good monitoring method is one that achieves a balance between the reliability of detection and cost requirements. Monitoring methods requiring the installation of expensive and intrusive sensors cannot be justified for all machines. Therefore, a new method for the monitoring of ground insulation condition for inverter-fed machines applying common-mode voltage at motor standstill is proposed in this paper. The proposed method utilizes the commonly used sensors usually employed for differential protection and is simple in its application. It can be implemented whenever the motor is off-line for a short period of time and can screen out severe insulation deterioration that could lead to forced outages. The method has been verified experimentally in the lab on two, 380 V, 18.5 kW and 5.5 kW induction machines.
科研通智能强力驱动
Strongly Powered by AbleSci AI