激发试验
医学
听力学
体格检查
感觉
握力
外围设备
物理疗法
外科
心理学
内科学
神经科学
替代医学
病理
作者
Seyed Mohammad MIRBOD,Farhang Akbar‐Khanzadeh,Minoru Onozuka,Marjan Jamali,Kazuko Watanabe,Riyoichi INABA,Hirotoshi Iwata
出处
期刊:Industrial Health
[National Institute of Occupational Safety and Health]
日期:1999-10-01
卷期号:37 (4): 415-425
被引量:26
标识
DOI:10.2486/indhealth.37.415
摘要
Fifty-three grinders in the metal industry were re-examined 4 years after their first examination. Information about age, occupation, daily vibration exposure, drinking and smoking habits, and presence of subjective symptoms such as vibration-induced white finger (VWF), and numbness and pain in the fingers was collected during the first and second examination. Cold provocation test (10 degrees C/10 min) was also employed to evaluate disturbances in the peripheral circulatory and peripheral nerves in all subjects. The frequency-weighted vibration acceleration of various types of hand-held tools was measured. There was no subject with VWF at the first examination; however, during the course of follow-up, two cases (3.8%) of VWF with latent interval of more than 25 years were diagnosed. Prevalence of numbness in the fingers and shoulder stiffness was significantly higher at the second examination. When the prevalence of subjective symptoms was tested by the subjects' total operating time (TOT) during the 4-year follow-up period, those whose TOT was equal to or more than 2500 hours showed higher prevalence compared to the other subgroup. The paired values of recovery rate of finger skin temperature and vibration sensation threshold after the cold water immersion test were significantly different at the first and second examination. On average, the diminution of hand-grip force during the 4-year follow-up course was 7.4%; the difference being significant at 0.01 level. Significant differences in the paired data of pinching power and tapping ability could be detected. The frequency-weighted vibration acceleration of various tools was in the range of 1.1-4.6 m/s2. It was concluded that: (1) prolonged occupational exposure to the vibration of hand-held grinding tools should be considered as a risk factor causing disturbances in the hand-arm system of the operators; (2) the results of recovery rate of finger skin temperature and the vibration sensation threshold seemed to be appropriate indicators for the assessment of peripheral vascular and peripheral nerve disturbances in workers exposed to hand-arm vibration; and (3) to reduce the subjects' physical stress, attention should be paid to ergonomic factors.
科研通智能强力驱动
Strongly Powered by AbleSci AI