The characterization parameters are summarized for performance evaluation of molten salt system in TiCl4molten salt chlorinator,and a preliminary analysis of its influencing factors is carried out.The causes of molten salt system deterioration during TiCl4 molten salt chlorination are analyzed based on production practice.According to the causes of molten salt system deterioration and the related factors,control measures for molten salt system stability are presented.