C. W. Oates,Zeb W. Barber,J. E. Stalnaker,Chad Hoyt,Yann Le Coq,L. Hollberg
标识
DOI:10.1364/ls.2007.ltuh3
摘要
We report new measurements for two optical atomic clocks. The calcium clock uses freely expanding atoms, while the ytterbium clock uses lattice-confined atoms to suppress Doppler effects. We measure a fractional instability between the clocks of 4 × 10−16 for 100 s averaging time.