Besides the chromatography techniques which are used to study
the concentration shanking, the electrochemical methods like
cyclic voltammetry (CV), differental pulse voltammetry (DPV) or
alternating current voltammetry (AC voltammetry) we be can
applied. All of these measurements are based on the direct
electrochemical reduction of PCBs in nonaqueous media. This
work deals with informations about the electrochemical
properties of the commercially produced mixture Delor 103 and
Delor 106 (Chemko, Stražske, Slovensko) at silver solid amalgam
electrode (Ag-SAE). We present results for the detection of
Delor 103 and 106 in 0.05 M solution of tetrabutylammonium
perchlorate in N,N-dimethylformamide. The electrochemical
behaviour of PCBs was studied by cyclic voltammetry (CV) and
with elimination voltammetry with linear scan (EVLS) as well.