降级(电信)
光伏系统
腐蚀
机制(生物学)
环境科学
材料科学
计算机科学
冶金
工程类
电气工程
电信
物理
量子力学
作者
Qiuyue Xu,Chunjie Wang,Jiajin Zou,Peng Chen
出处
期刊:
[Institute of Electrical and Electronics Engineers]
日期:2025-08-03
卷期号:: 1426-1430
标识
DOI:10.1109/icma65362.2025.11120749
摘要
Offshore photovoltaic systems pose severe challenges to the performance of photovoltaic connectors in the high salt spray environment of the ocean. This paper systematically studies the Galvanic corrosion mechanism and electrical performance degradation law of two common conductive materials, namely silver-plated copper and tin-plated copper, in the inner core of photovoltaic connectors. By constructing a three-dimensional Galvanic corrosion kinetics model and combining it with a 600-hour accelerated corrosion simulation, it was found that the synergistic effect of CI-and O2significantly exacerbated the galvanic corrosion at the defects of the metal coating. The contact resistance of tin-plated copper increases due to the deposition of tin oxidation products (SnCl2). Silver-plated copper shows a passive film protection effect in the complete coating area. The deposition thickness of corrosion products is relatively thin, and its passive stability is better than that of tin-plated copper. The simulation results show that the contact resistances of tin-plated copper and silver-plated copper conductors increase by 79.8 milliohm and 23.5 milliohm respectively, thereby causing overheating and even arc hazards. This research provides theoretical support for the optimal selection and life prediction of photovoltaic connectors in offshore photovoltaic systems.
科研通智能强力驱动
Strongly Powered by AbleSci AI