Comparing Measurements of CT Angiography, TEE, and Fluoroscopy of the Left Atrial Appendage for Percutaneous Closure

透视 医学 核医学 放射科 经皮 心脏病学
作者
Jacqueline Saw,Peter Fahmy,Ryan Spencer,Roshan Prakash,Patrick D. McLaughlin,Savvas Nicolaou,Michael Tsang
出处
期刊:Journal of Cardiovascular Electrophysiology [Wiley]
卷期号:27 (4): 414-422 被引量:91
标识
DOI:10.1111/jce.12909
摘要

Left atrial appendage (LAA) closure requires accurate preprocedural measurements, and trans-esophageal echocardiography (TEE), cardiac computed tomography angiography (CCTA) and fluoroscopy can be utilized. However, correlations between these measurements remain inadequately assessed.Patients who underwent LAA closure at Vancouver General Hospital who had baseline LAA measurements by CCTA, TEE, and fluoroscopy were included in this analysis. CCTAs were performed with prospective-ECG-gating with Toshiba 320-detector or Siemens second generation 128-slice dual-source scanners, and images interpreted with VitreaWorkstation.™ LAA maximal dimensions were obtained for all patients at: (1) Amplatzer Cardiac Plug (ACP)/Amulet landing zone 10 mm within orifice, (2) WATCHMAN ostium, and (3) WATCHMAN depth measurements. Correlations and agreements were compared.We report 50 consecutive patients who underwent LAA closure (8 ACP, 10 Amulet, 32 WATCHMAN). Average age was 75.2 ± 8.7 years, mean CHADS2 score 3.0 ± 1.3, and CHA2 DS2 -VASc 4.7 ± 1.5. Procedural device implantation success was 100%. For ACP landing zone, mean maximal measurements were 24.1 ± 4.7 mm with CCTA, 22.3 ± 4.9 mm TEE, and 19.9 ± 5.6 mm fluoroscopy (P < 0.001); R value 0.81 fluoroscopy/CTA, 0.67 fluoroscopy/TEE, and 0.80 CTA/TEE. For WATCHMAN ostium, mean maximal measurements were 25.8 ± 4.7 mm CCTA (P < 0.001 vs. fluoroscopy, P = 0.16 vs. TEE), 25.1 ± 4.4 mm TEE (P = 0.016 vs. fluoroscopy), and 23.8 ± 4.9 mm fluoroscopy; R value 0.71 fluoroscopy/CTA, 0.65 fluoroscopy/TEE, and 0.74 CTA/TEE. Depth measurements were 34.3 ± 5.7 mm with CCTA, 31.1 ± 6.5 mm TEE, and 27.8 ± 7.1 mm fluoroscopy (all P < 0.01); and correlations with R value 0.28 fluoroscopy/CTA, 0.22 fluoroscopy/TEE, and 0.56 CTA/TEE.All 3 imaging modalities correlated with ACP landing zone and WATCHMAN ostium measurements, with CCTA providing the largest measurements, followed by TEE and fluoroscopy.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
cherylizan完成签到,获得积分10
1秒前
小朋友完成签到,获得积分10
3秒前
这么年轻压根睡不着完成签到 ,获得积分10
4秒前
慕青应助科研通管家采纳,获得10
7秒前
7秒前
7秒前
7秒前
Ava应助科研通管家采纳,获得10
7秒前
小马甲应助科研通管家采纳,获得10
7秒前
情怀应助科研通管家采纳,获得10
7秒前
bkagyin应助科研通管家采纳,获得10
7秒前
英姑应助科研通管家采纳,获得10
7秒前
bkagyin应助科研通管家采纳,获得10
7秒前
7秒前
7秒前
小蘑菇应助科研通管家采纳,获得10
7秒前
7秒前
QIQ完成签到,获得积分10
9秒前
周六八应助大观天下采纳,获得10
9秒前
fm完成签到,获得积分20
9秒前
10秒前
CodeCraft应助坐亭下采纳,获得10
10秒前
简墨完成签到,获得积分10
10秒前
mouxq发布了新的文献求助10
12秒前
隔壁老王完成签到,获得积分10
12秒前
13秒前
orixero应助LiangYongrui采纳,获得10
14秒前
小林发布了新的文献求助10
15秒前
愉快的便当关注了科研通微信公众号
17秒前
看论文发布了新的文献求助20
18秒前
summer发布了新的文献求助10
18秒前
18秒前
21秒前
SciGPT应助超级的笑蓝采纳,获得10
22秒前
坐亭下发布了新的文献求助10
23秒前
25秒前
27秒前
嘉嘉子完成签到,获得积分10
29秒前
31秒前
32秒前
高分求助中
请在求助之前详细阅读求助说明!!!! 20000
One Man Talking: Selected Essays of Shao Xunmei, 1929–1939 1000
Yuwu Song, Biographical Dictionary of the People's Republic of China 700
[Lambert-Eaton syndrome without calcium channel autoantibodies] 520
Pressing the Fight: Print, Propaganda, and the Cold War 500
Bernd Ziesemer - Maos deutscher Topagent: Wie China die Bundesrepublik eroberte 500
The Three Stars Each: The Astrolabes and Related Texts 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 有机化学 工程类 生物化学 纳米技术 物理 内科学 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 电极 光电子学 量子力学
热门帖子
关注 科研通微信公众号,转发送积分 2470685
求助须知:如何正确求助?哪些是违规求助? 2137471
关于积分的说明 5446445
捐赠科研通 1861584
什么是DOI,文献DOI怎么找? 925807
版权声明 562721
科研通“疑难数据库(出版商)”最低求助积分说明 495235