Removal of antimony by volatilization from an industrial copper matte or white metal was carried out at 1, 523 K. The experimental conditions favored to the effective removal of antimony was selected from the thermodynamic considerations.H2S gas was used as a bubbling gas to increase the partial pressure of sulfur and simultaneously the activity coefficient of antimony in the melt.The antimony concentrations both in the matte and white metal were effectively lowered by bubbling 10% H2S-Ar mixed gas into the melt under a reducing atmosphere.In the case of matte, for example, antimony was removed from 2, 000 mass ppm to a level of 10 mass ppm in 3.6 ks at a gas flow rate of 8.3 cc/s.