预定位
化学
抗体
体内分布
肽
双特异性抗体
抗原
多塔
结合
体内
放射免疫疗法
癌症研究
药理学
单克隆抗体
螯合作用
生物化学
体外
医学
免疫学
生物
数学
有机化学
生物技术
数学分析
作者
Robert M. Sharkey,William J. McBride,Habibe Karacay,Ken Chang,Gary L. Griffiths,Hans J. Hansen,David M. Goldenberg
出处
期刊:PubMed
日期:2003-01-15
卷期号:63 (2): 354-63
被引量:94
摘要
Multistep targeting systems represent highly selective alternatives to targeting systems using directly radiolabeled antibodies for diagnostic and therapeutic applications. A flexible bispecific antibody (bsMAb) multistep, pretargeting system that potentially can be developed for use with a variety of different imaging or therapeutic agents is described herein. The flexibility of this system is based on use of an antibody directed against histamine-succinyl-glycine (HSG) and the development of peptides containing the HSG residue. HSG-containing peptides were synthesized with either 1,4,7,10-tetraazacyclododecane-N,N',N",N"'-tetraacetic acid for the chelation of 111In, 90Y, or 177Lu, or a technetium/rhenium chelate. The peptides can be radiolabeled to a high specific activity in a facile manner that avoids the need for purification. In vivo studies in nude mice bearing human colon tumor xenografts showed that the radiolabeled peptides cleared rapidly from the body with minimal retention in tumor or normal tissues. For pretargeting, these peptides were used in combination with a bsMAb composed of the anti-HSG Fab' that was covalently coupled with the Fab' of either an anticarcinoembryonic antigen or an anticolon-specific antigen-p antibody to provide tumor targeting capability. When the radiolabeled peptides were administered 1-2 days after a pretargeting dose of the bsMAbs, tumor uptake of the radiolabeled peptides increased as much as 28-175-fold over that seen with the peptides alone with tumor:nontumor ratios exceeding 2:1 to 8:1 within just 3 h of the peptide injection, which was a marked improvement over the tumor:nontumor ratios seen with a directly radiolabeled 99mTc-anti-anticarcinoembryonic antigen Fab' at this same time. The anticolon-specific antigen-p x anti-HSG F(ab')2 bsMAb had the highest and longest retention in the tumor, and when used in combination with the 111In-labeled peptide, radiation dose estimates for therapeutic radionuclides, such as 90Y and 177Lu, suggested that antitumor effects would be expected with tolerable radiation exposure to the normal tissues. These results suggest that this multistep, pretargeting system has diagnostic imaging and therapeutic potential.
科研通智能强力驱动
Strongly Powered by AbleSci AI