外淋巴
医学
耳蜗
脑脊液压力
人工耳蜗植入
脑脊液
套管
筛板
颅内压
解剖
外科
听力学
内科学
作者
John M. Graham,P Ashcroft
出处
期刊:PubMed
日期:1999-03-01
卷期号:20 (2): 205-8
被引量:12
摘要
Perilymph/cerebrospinal fluid (CSF) "gushers" may occur at cochleostomy during cochlear implant surgery, particularly in patients with congenital cochlear duct malformation in which CSF in the internal auditory meatus is in direct communication with the perilymphatic space in the cochlea. The object of the study was to measure the pressure and flow of a CSF gusher at cochleostomy.The design was a preoperative pressure measurement.The setting was a multidisciplinary cochlear implant program.A 4-year-old girl with bilateral Mondini deformity undergoing cochlear implantation was studied.A size 23 FG intravenous cannula was inserted into the cochlea and connected to a pediatric drip set to form an improvised manometer.Intracochlear fluid pressure was measured at 14 cm H2O, equivalent to the normal CSF pressure that would be recorded in a child of this age at lumbar puncture. An indirect measurement of the likely size of the CSF/perilymph defect was made.This technique may allow better assessment of the risk of postoperative CSF leakage and meningitis.This simple technique of measuring the pressure in a perilymph gusher can be used to assess the need for careful sealing of the cochleostomy, to measure the reduction in pressure produced by head elevation or a spinal drain, and to assess the probable size of a defect in the lamina cribrosa.