分光计
中子
计算机科学
同轴
中子温度
探测器
核工程
工艺工程
光学
物理
核物理学
工程类
电信
作者
Yujie Qiao,Weijia Zhao,Huimin Hei,Yafei Han,Qiang Wang,Kaihong Fang,Shuo Zhang
标识
DOI:10.1016/j.apradiso.2023.111010
摘要
The currently widely used multi-sphere neutron spectrometers still have many drawbacks, including complex design and processing, the need for multiple moderating spheres, high costs, large volumes, and complicated measurement procedures. This work proposes the portable cylindrical water injection multilayer neutron spectrometer (CWNS) as a promising alternative based on water pumping injection. The structure of CWNS consists of a central thermal neutron detector and a surrounding 6-layer of coaxial cylindrical water bags with varying diameters. During non-measurement periods, this CWNS is convenient to carry due to the absence of the need to inject moderating water. To optimize the CWNS design, we employed FLUKA simulation software to study and refine various parameters, including the thickness of the water bag, the material composition of the water bag, and the parameters of the supporting column. We finally achieved an optimized design. Specifically, the water bag of the CWNS is constructed using a 0.3 mm thick polyethylene film. The supporting column for the water bag is made of aluminum, providing stability and support to the overall structure. These optimized design parameters determine the specific size and configuration of the CWNS. The CWNS offers the benefits of convenient carrying, simplified processing, cost-effectiveness, and straightforward measurement. It has a promising potential use for the directional neutron dose monitoring.