Zhuolin Yuan,Aidong Tan,Jiwei Shan,Zhang Liu,Chang Liu,Ping Liu,Jianguo Liu
摘要
Abstract In proton exchange membrane (PEM) water electrolysis, H 2 content in O 2 (HiO) caused by H 2 diffusion from cathode to anode is a critical safety parameter, yet current research exhibits inconsistencies in HiO values and curve patterns. This study employs dual‐scale analysis to investigate HiO evolution mechanisms. From a temporal perspective, we reproduce all HiO curve types observed in the literature by controlling operation time. HiO increases with extended operation duration due to PEM water channel enlargement. Cathode water output emerges as an effective descriptor for water channel sizes and HiO. From a spatial perspective, catalyst layers (CLs) dominate at low current densities by influencing H 2 permeation driving force. PEM water channels contribute at medium current densities via diffusion resistance. At high current densities, CLs—porous transport layers interface become dominant due to local H 2 supersaturation. This work provides the first systematic framework for understanding HiO mechanisms, unifying conflicting literature findings.
科研通智能强力驱动