医学
经皮
外科
血管闭合器
狭窄
队列
腹股沟
腔内修复术
临床终点
腹主动脉瘤
纤维接头
前瞻性队列研究
动脉瘤
血管通路
放射科
假性动脉瘤
导管
结束语(心理学)
试验装置豁免
回顾性队列研究
队列研究
阶段(地层学)
随机对照试验
作者
Sven Ross Mathisen,Simen Tveten Berge
出处
期刊:Vascular
[SAGE Publishing]
日期:2026-02-24
卷期号:34 (4): 810-818
被引量:1
标识
DOI:10.1177/17085381261429288
摘要
Objectives To evaluate efficacy and safety of percutaneous-endovascular aneurysm repair (p-EVAR) where large-bore access puncture holes were closed with a suture mediated closure device (SMCD) in all eligible patients. Methods A single-center cohort of prospectively collected data in an Internal Quality Control Registry (IQCR). An “All Comers” cohort of 368 patients with 736 access groins was assessed. All abdominal aortic aneurysm (AAA) patients eligible for p-EVAR after CTA evaluation were included. Patients with stenosis and occlusions requiring vascular Interventions during EVAR were excluded. The groins were stratified into two groups: low-profile (12Fr – 16Fr) and high-profile introducers (18Fr - 20Fr). PerClose ProGlide (Abbott Cardiovascular, IL, USA) and later the newer version PerClose ProStyle (Abbott Cardiovascular, IL, USA) SMCD devices were assessed. Primary endpoints were: Primary ProGlide technical success and Primary assisted percutaneous and non-invasive technical success. Secondary cutdown was an exclusions criterion. Safety endpoints were Freedom from early peri-operative and late 30-day groin access complications requiring vascular surgical intervention. Results Primary technical success was achieved in 66.4 % (473/712) groins . Primary assisted percutaneous and non-invasive technical success was achieved in 32.2 % (229/712) groins. Continuous hemorrhage in 1.4 % (10/712) groins required a cutdown. 98.6 % (712/736) of the groins were successfully closed percutaneously. Median age was 76 years (IQR 71, 80). 78.8 % were male. 92 % (330/368) of the p-EVAR were elective. Median AAA diameter was 57mm (IQR 53, 63). Few groins required surgical intervention. No statically significant differences were found between the PerClose ProGlide and the ProStyle (p < .05). Conclusions Percutaneous closure is efficient and safe. Low-profile introducers and EVAR components (12Fr – 16Fr) had slightly better primary technical and assisted technical success. 83.5 % of the patient groins were treated with low-profile introducers reflecting the drive in the vascular field toward lower-profile devices. No statistical difference between groups was observed for primary technical success and complication rate.
科研通智能强力驱动
Strongly Powered by AbleSci AI