作者
Zheng Lu,Hengrui Zhang,Bin Zhao,Xianjie Li
摘要
Summary In this paper, the influence of mass ratio on the vibration control effects of tuned mass damper (TMD) on a super high‐rise building has been investigated. A 1/45 scaled model of a super high‐rise building was constructed, and the TMD with the mass ratio of 0.01, 0.02, and 0.03, respectively, was suspended on the top. Shaking table test and the corresponding numerical simulation were carried out to make a further understanding of the damping mechanism. The structural performance with or without TMD was comparatively studied. The results show that larger mass ratio can improve the control effects under frequent earthquake, but the control effects increase little with the increase of mass ratio under rare earthquake due to structural damages, accompanied by stiffness degradation and nonlinear behavior of the main structure. In addition, some suggestions on the mass ratio selection are also proposed to generalize its applications.