作者
S. Girija,S. Karthika,J.I.B. Wilson
标识
DOI:10.1016/j.rechem.2024.101527
摘要
Cadmium ion detection is an important area of research since it is associated with numerous diseases in humans and the environment. In this study, selective Cd2+ ion detection using polypyrrole and ZIF-12 was investigated using the square wave voltammetry technique. A convenient chemical method is used to polymerize the pyrrole to form a composite, which provides a better electroactive surface area of 24.5 x 10-3 m2 for the ZIF-12@Ppy composite modified GCE. The –NH2 functional group in polypyrrole makes good adsorptive property for Cd2+ ion capture with a detection range of 10 µM to 5 mM, the regression equation of y = 0.0102 x + 43.289, and low detection limit of approximately 50 nM as a result of enhanced electrocatalytic activity. The good anti-interference properties, repeatability, and stability of the prepared composite successfully demonstrated for the detection of Cd2+ ions in real samples from various water sources. Overall, these studies provide good insights into the development of an effective device for the detection of Cd2+ ions using polypyrrole and ZIF-12 platform.