医学
植入
静脉通路
心脏起搏
铅(地质)
腋静脉
超声波
倾斜(摄像机)
心脏病学
外科
内科学
放射科
导管
血栓形成
工程类
地质学
地貌学
机械工程
作者
Risheek Kaul,Felix Yang,Mohamed Shokr,Lior Jankelson,Robert J. Knotts,Douglas Holmes,Anthony Aizer,Larry A. Chinitz,Chirag R. Barbhaiya
出处
期刊:Heart Rhythm
[Elsevier BV]
日期:2024-01-22
卷期号:21 (5): 662-667
被引量:3
标识
DOI:10.1016/j.hrthm.2024.01.026
摘要
The optimal technique for venous access (VA) in cardiac implantable electronic device (CIED) implant procedures is unclear 1 Davis L. Chik W. Kumar S. Sivagangabalan G. Thomas S.P. Denniss A.R. Axillary vein access using ultrasound guidance, Venography or Cephalic Cutdown-What is the optimal access technique for insertion of pacing leads?. J Arrhythm Dec. 2021; 37: 1506-1511 Crossref Scopus (2) Google Scholar . Ultrasound guided (US) axillary VA has been established as a safe, effective, and efficient technique for CIED implantation 2 Tagliari A.P. Kochi A.N. Mastella B. Saadi R.P. di Leoni Ferrari A. Saadi E.K. Polanczyk C.A. Axillary vein puncture guided by ultrasound vs cephalic vein dissection in pacemaker and defibrillator implant: A multicenter randomized clinical trial. Heart Rhythm Sep. 2020; 17: 1554-1560 Abstract Full Text Full Text PDF PubMed Scopus (0) Google Scholar . Optimal technique for US guided axillary VA requires imaging and puncture of the “extrathoracic portion” of the axillary vein 2 Tagliari A.P. Kochi A.N. Mastella B. Saadi R.P. di Leoni Ferrari A. Saadi E.K. Polanczyk C.A. Axillary vein puncture guided by ultrasound vs cephalic vein dissection in pacemaker and defibrillator implant: A multicenter randomized clinical trial. Heart Rhythm Sep. 2020; 17: 1554-1560 Abstract Full Text Full Text PDF PubMed Scopus (0) Google Scholar . Therefore, a limitation of ultrasound (US) guided axillary VA is that venous entry may be lateral to the thoracic cavity in order to avoid puncture of intrathoracic structures (Figure 1). Lateral extrathoracic VA may result in greater patient discomfort 3 Cosgun M.S. Cosgun C. Relationship between CIED extent of displacement toward the shoulder while in the supine position and shoulder impairment. Pacing Clin Electrophysiol Nov. 2022; 28 Google Scholar , more acute bends as the lead traverses from the pocket to the heart, and a requirement for longer leads. Caudal-tilt fluoroscopy, first described by Lau 4 Lau E.W. Navigation by parallax in three-dimensional space during fluoroscopy: application in guide wire-directed axillary/subclavian vein puncture. Pacing Clin Electrophysiol Sep. 2007; 30: 1054-1066 Crossref PubMed Scopus (0) Google Scholar as the parallax technique and then further detailed by Yang and Kulbak, is an established technique for visualization of the space between the anterior border of the first rib and the clavicle to facilitate a more medial axillary VA with reduced pneumothorax risk 5 Yang F. Kulbak G. A new trick to a routine procedure: taking the fear out of the axillary vein stick using the 35 degrees caudal view. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology Jul. 2015; 17: 1157-1160 Crossref Scopus (22) Google Scholar ,6 Burri H. Starck C. EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS)-a role for postoperative ultrasound? Authors' reply. Europace Mar 2. 2022; 24: 523-524 Google Scholar . Feasibility of caudal-tilt US guidance for more medial US guided axillary VA is unknown. We aimed to compare acute procedural outcomes of device implants utilizing caudal US guided axillary VA to those of standard, vertically oriented US guided axillary VA.
科研通智能强力驱动
Strongly Powered by AbleSci AI