医学
骨切除术
畸形
内翻畸形
股骨
外科
植入
口腔正畸科
骨关节炎
病理
替代医学
作者
Jose L. Carvajal,Stanley E. Kim
摘要
To report the successful correction of a proximal femoral deformity (PFD) and total hip arthroplasty (THA) in a dog with the use of three-dimensionally (3D) printed custom surgical guides (CSGs).Case report.One-year-old, male neutered, Goldendoodle.Uniapical proximal varus and recurvatum femoral deformity (PFD) precluded femoral stem placement for THA, which was indicated for severe hip dysplasia. Using CT-derived bone and implant models, custom ostectomy and reduction guides for deformity correction were designed. A 13-hole 3.5 mm locking compression plate was contoured and applied to 3D printed models of the corrected femur and screw trajectory holes were incorporated into the CSGs.A caudolateral closing wedge ostectomy of the proximal femur was achieved with the aid of the CSGs and precontoured plate to within 2° of varus and 1° of recurvatum of the virtual surgical plan. Placement of a press-fit femoral stem was achieved with 7° of varus and 9° of caudal angulation. The plate was secured using six locking screws, two cortical screws, and two 18-gauge double-loop cerclage wires. No lameness and normal range of motion of the hip were observed on clinical examination 3 months after surgery. Radiographs at 3 and 6 months revealed static implant positioning, and complete bony union at the ostectomy site.Virtual surgical planning and CSGs led to successful concurrent THA and femoral deformity correction.
科研通智能强力驱动