鲁米诺
电化学发光
检出限
化学发光
材料科学
二氧化钛
纳米技术
化学
色谱法
光电子学
冶金
作者
Zhihao Wei,Huixin Zhang,Zonghua Wang
标识
DOI:10.1021/acsami.2c19539
摘要
Luminol is a classic electrochemiluminescence (ECL) luminophore. The luminol–O 2 ECL system suffers from a problem, that is, the conversion rate of dissolved O 2 into reactive oxygen species (ROS) is low. In this work, we used high-intensity focused ultrasound (HIFU) pretreatment combined with Ti 3 C 2 –TiO 2 to construct a highly sensitive luminol–O 2 ECL system for the specific detection of polynucleotide kinase (PNK) first. On the one hand, HIFU generated ROS in situ as a coreactant via the cavitation effect to boost the luminol emission. On the other hand, Ti 3 C 2 –TiO 2 was prepared in situ via Ti 3 C 2 as a reducing agent, and it can aggregate and catalyze ROS generated in situ by HIFU. Moreover, the Ti on the Ti 3 C 2 –TiO 2 surface could bind to phosphate groups through chelation, thereby realizing highly specific detection of PNK. The sensor has a linear relationship range of 1.0 × 10 –5 to 10.0 U mL –1, and the limit of detection is 1.48 × 10 –7 U mL –1, which is superior to most existing methods. The sensor performance in HeLa cell lysate was measured with a satisfactory result. The designed ECL biosensor has potential applications in biological analysis and clinical diagnosis.
科研通智能强力驱动
Strongly Powered by AbleSci AI