医学
呼吸机相关性肺炎
随机对照试验
子群分析
相对风险
荟萃分析
科克伦图书馆
机械通风
重症监护医学
置信区间
内科学
作者
Yanshuo Wu,Yanan Li,Meirong Sun,Jingjing Bu,Congcong Zhao,Zhenjie Hu,Y. Yin
标识
DOI:10.1177/08850666241232369
摘要
Objective This study aimed to evaluate the effect of continuous control cuff pressure (CCCP) versus intermittent control cuff pressure (ICCP) for the prevention of ventilator-associated pneumonia (VAP) in critically ill patients. Methods Relevant literature was searched in several databases, including PubMed, Embase, Web of Science, ProQuest, the Cochrane Library, Wanfang Database and China National Knowledge Infrastructure between inception and September 2022. Randomized controlled trials were considered eligible if they compared CCCP with ICCP for the prevention of VAP in critically ill patients. This meta-analysis was performed using the RevMan 5.3 and Trial Sequential Analysis 0.9 software packages. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework was used to assess the level of evidence. Results We identified 14 randomized control trials with a total of 2080 patients. Meta-analysis revealed that CCCP was associated with a significantly lower incidence of VAP compared with ICCP (relative risk [RR] = 0.52; 95% confidence interval [CI]: 0.37-0.74; P < 0.001), although considerable heterogeneity was observed ( I 2 = 71%). Conducting trial sequential analysis confirmed the finding, and the GRADE level was moderate. Subgroup analysis demonstrated that CCCP combined with subglottic secretion drainage (SSD) had a more significant effect on reducing VAP (RR = 0.39; 95% CI = 0.29-0.52; P < 0.001). The effect of CCCP on ventilator-associated respiratory infection (VARI) incidence was uncertain (RR = 0.81; 95% CI = 0.53-1.24; P = 0.34; I 2 = 61%). Additionally, CCCP significantly reduced the duration of mechanical ventilation (MV) (mean difference [MD] = −2.42 days; 95% CI = −4.71-0.12; P = 0.04; I 2 = 87%). Descriptive analysis showed that CCCP improved the qualified rate of cuff pressure. However, no significant differences were found in the length of intensive care unit (ICU) stay (MD = 2.42 days; 95% CI = −1.84-6.68; P = 0.27) and ICU mortality (RR = 0.86; 95% CI = 0.74-1.00; P = 0.05). Conclusion Our findings suggest that the combination of CCCP and SSD can reduce the incidence of VAP and the duration of MV and maintain the stability of cuff pressure. A combination of CCCP and SSD applications is suggested for preventing VAP.
科研通智能强力驱动
Strongly Powered by AbleSci AI