Xiaoyi Xu,Tingting Zhou,Ao Yang,Hongtao Jiang,Zhao Song,Xukun Wang,Bing Yu,Liqiang Zhao,Tong Zhang
出处
期刊:ACS Sensors
[American Chemical Society]
日期:2025-02-06
卷期号:10 (2): 1483-1492
被引量:12
标识
DOI:10.1021/acssensors.4c03535
摘要
Monitoring the CO2 concentration is crucial for assessing respiratory illnesses in humans and safeguarding the environment. The ongoing difficulty lies in achieving highly sensitive detection while also eliminating the interference caused by humidity. There is an unmet need for portable sensors with both high sensitivity and good moisture resistance to monitor CO2 in real time. In this study, a novel sensor capable of capturing the piezoelectric signals induced by CO2 gas is developed. A quartz crystal microbalance (QCM) coated with a mixed- matrix membrane of metal-organic framework (MOF)/polyether block amide (Pebax) is designed as a transducer to detect CO2 at room temperature. The change in the concentration of CO2 can be detected by the frequency shift of the QCM sensor. The sensor shows an ultrahigh sensitivity of 371.8 Hz to 1000 ppm of CO2 because of the abundant polar group and nitrogen Lewis basic groups. Furthermore, the implementation of a self-humidity compensation algorithm significantly enhances the accuracy and reliability of CO2 concentration monitoring by effectively addressing the issue of humidity interference. Our research underscores the immense potential of MOF/Pebax QCM sensors with self-humidity compensation ability in the field of CO2 gas monitoring.