合金
钛
材料科学
聚乙烯
全髋关节置换术
铬
钛合金
冶金
体内
假肢
生物医学工程
医学
外科
复合材料
生物
生物技术
作者
Harry A. McKellop,Augusto Sarmiento,C. P. Schwinn,Edward Ebramzadeh
标识
DOI:10.2106/00004623-199072040-00007
摘要
We examined samples of tissue and components that had been removed during twenty revisions of total hip arthroplasties in which a titanium-alloy femoral component had been used. Minute amounts of metallic debris were detected in the tissues from two patients. The amounts of polyethylene and methylmethacrylate debris and the histological reactions in the tissues corresponded closely with those reported in earlier studies of total hip prostheses made of stainless steel or cobalt-chromium alloy.