PURPOSE: Intraoperative planning with transrectal ultrasound (US) is used for accurate seed placement and optimal dosimetry in prostate brachytherapy. However, prostate magnetic resonance imaging (MRI) has shown superiority in delineation of prostate anatomy. Accordingly, MRI/US fusion may be useful for accurate intraoperative planning. We analyzed planning with MRI/US fusion to compare differences in dosimetry and volume to that derived from the postoperative computed tomography (CT). MATERIAL AND METHODS: . RESULTS: = 0.009). CONCLUSIONS: The MRI/US fusion demonstrated greater prostate volume compared to standard CT/US based planning likely due to the better resolution of the prostate apex. Furthermore, rectal dose was underestimated with CT vs. MRI based planning. Additional study is required to assess long-term clinical implications of disease control and effects on long-term toxicity, especially as related to the rectum and urinary sphincter. MRI/US intraoperative fusion may improve prostate dosimetry while sparing the rectum and urethra, potentially impacting disease control and late toxicity.