质谱法
化学
示踪剂
分析化学(期刊)
燃烧
色谱法
检出限
同位素比值质谱法
溶剂
蒸发
同位素
甲醇
气相色谱法
核物理学
有机化学
物理
热力学
作者
Willi A. Brand,P. Dobberstein
标识
DOI:10.1080/10256019608036320
摘要
Abstract A Liquid Chromatography-Combustion (LC-C) Interface, based on a moving wire technique, has been built and tested. The LC effluent is deposited onto a transport wire, which carries the sample through solvent evaporation and combustion ovens. CO2 from the combustion step is analysed in an isotope ratio mass spectrometer. Performance of the interface was tested by loop injections of sucrose and glucose into a liquid flow of methanol/water (80/20). Accuracy and precision of δ13CPDB < 1‰ was achieved for sample concentrations > 500 ng/ul (5μl loop), sufficient for studies at natural isotope ratios. In case of 13C tracer applications the detection limit was determined to be about 20 pg carbon tracer (on wire).