水槽
生活污水管
连接(主束)
入侵
热成像
红外线的
遥感
环境科学
计算机科学
材料科学
地质学
光学
结构工程
工程类
几何学
环境工程
物理
流量(数学)
数学
地球化学
作者
Mathieu Lepot,Konstantinos F. Makris,F.H.L.R. Clemens
出处
期刊:Water Research
[Elsevier BV]
日期:2017-06-12
卷期号:122: 678-691
被引量:45
标识
DOI:10.1016/j.watres.2017.06.030
摘要
Separate sewer systems are sensitive to illegal or mis-connections. Several techniques (including the Distributed Temperature Sensor) are now available to identify and locate those connections. Based on thermal fingerprints, DTS allows the localization of each lateral connection along a reach. The use of Infra-Red camera has been investigated with 748 laboratory experiments (artificial connections along a flume). The tested connections vary in diameters (from 75 to 200 mm), lengths of intrusion (from 0 to 200 m), shapes (circular or linear i.e. cracks), depths, discharge rates between the lateral connection and the main flume, and temperatures. IR frame analysis (for detection) and 2D temperature mapping (at the free water surface, for quantification) demonstrate that: i) the detection limit is very low (ratio between lateral and main discharges: 0.025) and ii) the quantification of the lateral discharge is impossible. Application of an IR camera seems to be a promising technique to detect lateral connections.
科研通智能强力驱动