Optimization and Electrochemical Testing of 3-Electrode Pouch Cell for Insights into Battery Prototyping
作者
Alexander John Roberts,Agata Greszta,Wuttichai Somyanonthanakun
出处
期刊:Meeting abstracts [Institute of Physics] 日期:2024-11-22卷期号:MA2024-02 (2): 248-248
标识
DOI:10.1149/ma2024-022248mtgabs
摘要
When promising new materials are discovered and assessed for their electrochemical performance in batteries or other energy storage devices, their testing is typically performed initially in small coin cells, progressing to the single layer pouch cell (SLP) and on to commercially relevant prototype devices in various cell formats. As this development process moves from laboratory to commercial reality, the findings at coin cell level and SLP are typically used at an early stage to inform on expected performance. It is often the case that some device performance metrics obtained at SLP scale to those of a final prototype or commercial device, with other metrics from the same cell not giving a true indication. In this work, we initially look to answer the question ‘what size does my test cell have to be to inform on final device performance?’ This is done through variation of design and size of Li-ion pouch cells, from coin to SLP, through multilayer pouch (MLP) cells of varied numbers of electrodes, and consideration of the relationship of cell parameters such as capacity, rate, resistance, and lifetime relative to those of final MLP prototype device. A further challenge in the assessment and development of new materials performance and properties as we move from lab to commercially relevant prototype lies in understanding the potentials that individual electrodes experience in larger cell formats. Whilst this is relatively straightforward at the small scale with various methods of constructing coin/ Swagelok test cells with a reference electrode (3-electrode cells), as we move to SLP and MLP, this becomes significantly more challenging. Through the monitoring of individual electrode potentials in the larger format cell, invaluable information can be obtained, for example, for tailoring cell balance for application, helping to develop new algorithms for fast charging and understanding the effects of rate on lifetime. Having considered the necessary cell size to inform on performance of final prototype device, this information has been used in the development of a 3-electrode cell, with the effect of reference electrode size and position, on anode and cathode potential measurement along with cell performance.