期刊:Spanish Conference on Electron Devices日期:2009-02-01卷期号:78: 57-60被引量:1
标识
DOI:10.1109/sced.2009.4800429
摘要
Ohmic contacts with low resistivity values to Si implanted GaN have been performed using a metal combination of Ti/Al. Different protection caps have been used during post-implantation annealing and their influences to the specific contact resistivity (rhoc) have been investigated. After the metal alloying, noticeable differences have been observed between the protected sample with SiO2and unprotected sample during the post-implantation annealing. The unprotected sample has shown lower values of rhocbut with very low reproducibility, while, by contrast, the use of SiO2cap has revealed the achievement of a low rhocaround 10-5Omega.cm2with very good uniformity. Based on the results obtained from electrical measurements, XRD (X-ray diffraction) analysis, AFM (atomic force microscopy) and SEM (scanning electron microscopy) observations, we discuss the mechanism for the uniformity in rhoc.