摘要
Partial discharge (PD) is a phenomenon often occurring in insulation system defects (cavities), which can significantly affect life and reliability. While broad knowledge on PD phenomenology of high-frequency transformers (HFT) has been achieved under ac sinusoidal voltage, much less work has been done to infer PD behavior under emerging high frequency pulsewidth modulation (PWM) operation conditions. An impediment has been the limited appropriate test equipment. A recently developed novel ±5 kV GaN-based high-frequency PWM supply with controllable dV/dt , voltage level and frequency has been developed. This article explores the application of these measurements to the testing of materials in this electrical environment. Two commonly used windings for HFT were tested under different applied voltage magnitudes, frequencies, and slew rates. According to the test results, at high frequency (up to 50 kHz) the electric field generated by space charge deposited by PD occurring during previous PWM pulses plays an important role in PD behavior. The frequency dependent permittivity of the insulation material can also affect PD measurement results.