曝气
活性污泥
缺氧水域
反硝化
流出物
活性污泥模型
氮气
化学
环境工程
制浆造纸工业
硝化作用
同步硝化反硝化
污水处理
环境科学
环境化学
工程类
有机化学
作者
Oytun Hanhan,Güçlü İnsel,Nevin Yağcı,N. Artan,Derin Orhon
标识
DOI:10.1080/10934529.2011.526073
摘要
The paper provided a comprehensive evaluation of the mechanism and design of intermittent aeration activated sludge process for nitrogen removal. Based on the specific character of the process the total cycle time, (T(C)), the aerated fraction, (AF), and the cycle time ratio, (CTR) were defined as major design parameters, aside from the sludge age of the system. Their impact on system performance was evaluated by means of process simulation. A rational design procedure was developed on the basis of basic stochiometry and mass balance related to the oxidation and removal of nitrogen under aerobic and anoxic conditions, which enabled selected of operation parameters of optimum performance. The simulation results indicated that the total nitrogen level could be reduced to a minimum level by appropriate manipulation of the aerated fraction and cycle time ratio. They also showed that the effluent total nitrogen could be lowered to around 4.0 mgN/L by adjusting the dissolved oxygen set-point to 0.5 mg/L, a level which promotes simultaneous nitrification and denitrification.