Abstract PD8-06: Fluorescence guided breast conserving surgery
作者
CK Sharma,Piyush Ranjan,Darakhshan Qaiser,Anita Dhar,Achal Kumar Srivastava,Kamal Kataria
出处
期刊:Cancer Research [American Association for Cancer Research] 日期:2019-02-15卷期号:79 (4_Supplement): PD8-06
标识
DOI:10.1158/1538-7445.sabcs18-pd8-06
摘要
Abstract Background. Palpation guided breast conserving surgery for breast cancer is associated with tumor involved margins in up to 41% of cases. Ultrasound guided breast conserving surgery and frozen section biopsy result in a significant reduction in margin positivity. However, intra-operative USG and Frozen section biopsy are not widely available. We aimed to find a simple and effective technique for intra-operative margin assessment during breast conserving surgery. Hypothesis. Intravenously injected Fluorescein reaches tumor tissue in high concentration due to increased tumor blood flow and increased capillary permeability which can be detected by blue light (494 nm). Objective. To find diagnostic accuracy of fluorescence guided identification of tumor margins during breast conserving surgery. Methods. A total of 60 patients with T1–T2 invasive breast cancer who underwent breast conserving surgery at AIIMS, New Delhi between March, 2016 to Feb, 2018 were included. Each patient received 2 ml of intra-venous 20% Fluorescein sodium just before skin incision. Breast conserving surgery was performed under USG guidance. Specimen was bisected and examined under blue light. Fluorescent tumor margins were identified and six biopsies taken from non-fluorescent area 5mm outside from fluorescent tumor margins at 2,4,6,8,10 and 12 o'clock position. The involvement of USG guided margin was compared with Fluorescence guided margins on histopathology. Results. Mean age of the patient was 51.2 (SD=6.4) years. Fourteen patients (20.3 %) had T1 tumors while 46 patients(69.7%) had T2 tumors. Axillary nodes were involved in 19 patients (20.1%) and all underwent axillary node dissection. Eight patients (13.3%) received NACT. Fluorescent margins in two (3.3%) out of 60 patients were involved by tumor while USG guided margins in all the 60 patients were free. The specificity of fluorescence in identifying uninvolved tumor margins during breast conserving surgery is 96.7%. No patient developed adverse drug reactions. Conclusion. The fluorescence identifies tumor free margins with 96.7% accuracy. It is simple, effective and affordable method of identifying margin positivity in breast conservation surgery. Citation Format: Sharma CK, Ranjan P, Qaiser D, Dhar A, Srivastava A, Kataria K. Fluorescence guided breast conserving surgery [abstract]. In: Proceedings of the 2018 San Antonio Breast Cancer Symposium; 2018 Dec 4-8; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2019;79(4 Suppl):Abstract nr PD8-06.