Thomas Stehlé,Fengjiang Wei,Séverine Brabant,Alain Luciani,Philippe Grimbert,Dominique Prié,Edouard Reizine,Antoine Dürrbach,Sebastien Mulé,Anne Hulin,Anna Boueilh,Maxime Blain,C. Champy,Alexandre Ingels,Marie Essig,Paul Brasseur,Florence Canouï‐Poitrine,F. Pigneur
出处
期刊:Radiology
[Radiological Society of North America]
日期:2023-12-01
卷期号:309 (3)
被引量:2
标识
DOI:10.1148/radiol.230567
摘要
Background Estimating glomerular filtration rate (GFR) from serum creatinine can be inaccurate, and current procedures for measuring GFR are time-consuming and cumbersome. Purpose To develop a method for measuring GFR based on iomeprol clearance assessed at CT urography in kidney donor candidates and compare this with iohexol clearance (reference standard for measuring GFR). Materials and Methods This cross-sectional retrospective study included data from kidney donor candidates who underwent both iohexol clearance and CT urography between July 2016 and October 2022. CT-measured GFR was calculated as the iomeprol excretion rate in the urinary system between arterial and excretory phases (Hounsfield units times milliliters per minute) divided by a surrogate for serum iomeprol concentration in the aorta at the midpoint (in Hounsfield units). Performance of CT-measured GFR was assessed with use of mean bias (mean difference between CT-measured GFR and iohexol clearance), precision (the distance between quartile 1 and quartile 3 of the bias [quartile 3 minus quartile 1], with a small value indicating high precision), and accuracy (percentage of CT-measured GFR values falling within 10%, 20%, and 30% of iohexol clearance values). Intraobserver agreement was assessed for 30 randomly selected individuals with the Lin concordance correlation coefficient. Results A total of 75 kidney donor candidates were included (mean age, 51 years ± 13 [SD]; 45 female). The CT-measured GFR was unbiased (1.1 mL/min/1.73 m2 [95% CI: −1.9, 4.1]) and highly precise (16.2 mL/min/1.73 m2 [quartiles 1 to 3, −6.6 to 9.6]). The accuracy of CT-measured GFR within 10%, 20%, and 30% was 61.3% (95% CI: 50.3, 72.4), 88.0% (95% CI: 80.7, 95.4), and 100%, respectively. Concordance between CT-based GFR measurements taken 2 months apart was almost perfect (correlation coefficient, 0.99 [95% CI: 0.98, 0.99]). Conclusion In living kidney donors, GFR measured based on iomeprol clearance assessed at CT urography showed good agreement with GFR measured based on iohexol clearance. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Davenport in this issue.
科研通智能强力驱动
Strongly Powered by AbleSci AI