医学
颈内静脉
超声波
外科
静脉丛
超声科
并发症
麻醉
放射科
作者
Azmat Riaz,Rao Ali Shan Khan,Faisal Salim
出处
期刊:PubMed
日期:2015-05-01
卷期号:25 (5): 315-9
被引量:7
摘要
To compare real-time ultrasonography-guided technique versus the traditional land-mark technique for internal Jugular venous cannulation.Randomized controlled trial.Department of Anaesthesia, Combined Military Hospital, Rawalpindi, from September 2013 to July 2014.A total of 200 patients who required internal jugular vein cannulation were randomly assigned using either real-time ultrasound-guided technique or land-mark technique. Access time, number of attempts until successful cannulation, complications and the demographics of each patient were recorded.Access time was significantly less in real-time ultrasound group (34.95 ± 11.47 vs. 146.59 ± 40.20 seconds, p < 0.001). Cannulation was performed in first attempt in 99% of patients in ultrasound group as compared to 89% of landmark group. Complication rate was significantly higher in the land-mark group than in the ultrasound-guided group. Carotid artery puncture rate (9% vs. 1%) and haematoma formation (7% vs. 0%) were more frequent in the land-mark group than in the ultrasound-guided group. Brachial plexus irritation was also more in land-mark group (6% vs. 0%).Access time, failure rate and procedure related complications are reduced when real-time ultrasonography is used to cannulate internal Jugular vein.
科研通智能强力驱动