医学
舱室(船)
筋膜切开术
筋膜间隔综合征
外科
麻醉
内科学
临床试验
海洋学
地质学
止痛药
作者
Kyle Dickson,Michael Sullivan,Bruce Steinberg,Leann Myers,Edward R. Anderson,Mitch Harris
出处
期刊:Orthopedics
[Slack Incorporated (United States)]
日期:2003-12-01
卷期号:26 (12): 1215-1218
被引量:27
标识
DOI:10.3928/0147-7447-20031201-11
摘要
This study compared the effectiveness of a commercially available invasive intracompartmental pressure measuring device with an investigational noninvasive hardness measuring device in 75 patients undergoing examination for possible compartment syndrome. Legs, forearms, thighs, and arms were tested. Pressure values and hardness ratios were compared to one another as continuous variables and to the clinical diagnosis of compartment syndrome as discrete variables. The compartment with the highest pressure reading within a limb diagnosed with compartment syndrome was compared to limbs without compartment syndrome. Due to the low specificity of the noninvasive measurement of hardness compared to the invasive pressure measurement (0.82 versus 0.96), this study does not support the use of the hardness monitor in the diagnosis of compartment syndrome.
科研通智能强力驱动
Strongly Powered by AbleSci AI