人工尿道括约肌
泌尿系统
泌尿科
医学
计算机科学
尿失禁
内科学
作者
Ali Bourgi,F. Bruyère,Hugo Crespin
摘要
Background: Artificial urinary sphincter (AUS) is the gold standard for severe male stress urinary incontinence (SUI). This study aims to evaluate the interest of a new cutaneous preparation regarding the risk of early device infection. Methods: A retrospective review of medical records has been built with all patients who underwent an AUS, implanted by experienced surgeons, between January 2010 and January 2023. Before January 2015, all AUS received a standard protocol (SP) of cutaneous cleansing with soap povidone iodine and disinfection with alcoholic povidone iodine. After January 2015, all AUS received the new protocol (NP) with two cleansings with soap povidone iodine and two disinfections with alcoholic povidone iodine. The primary focus was to compare the risk of early device infection between the two protocols. Multivariate analyses were done with several risk factors such as age, diabetes, underlying pathology (prostate cancer surgery, surgical treatment of benign prostatic hyperplasia or others), past history of pelvic radiation therapy and past AUS implantation. Results: 25%, P=0.09). The was no difference between the NP and the SP in multiparametric analysis [odds ratio (OR): 0.97; P=0.96]. No other risk factors were associated with increased risk of AUS removal. Conclusions: Our study showed no correlation between the two types of skin preparation and the risk of AUS removal or revision. Future studies are needed to highlight the legitimate risk factors.
科研通智能强力驱动
Strongly Powered by AbleSci AI