Non-contact infrared thermometers compared with current approaches in primary care for children aged 5 years and under: a method comparison study

温度计 医学 四分位间距 置信区间 儿科 外科 内科学 量子力学 物理
作者
Ann Van den Bruel,Jan Y Verbakel,Kay Wang,Susannah Fleming,Gea A. Holtman,Margaret Głogowska,Elizabeth Morris,George Edwards,Fatene Abakar Ismail,Kathryn Curtis,James Goetz,Grace Barnes,Ralitsa Slivkova,Charlotte Nesbitt,Suhail Aslam,Ealish Swift,Harriet Williams,Gail Hayward
出处
期刊:Health Technology Assessment [NIHR Journals Library]
卷期号:24 (53): 1-28 被引量:11
标识
DOI:10.3310/hta24530
摘要

Background Current options for temperature measurement in children presenting to primary care include either electronic axillary or infrared tympanic thermometers. Non-contact infrared thermometers could reduce both the distress of the child and the risk of cross-infection. Objectives The objective of this study was to compare the use of non-contact thermometers with the use of electronic axillary and infrared tympanic thermometers in children presenting to primary care. Design Method comparison study with a nested qualitative study. Setting Primary care in Oxfordshire. Participants Children aged ≤ 5 years attending with an acute illness. Interventions Two types of non-contact infrared thermometers [i.e. Thermofocus (Tecnimed, Varese, Italy) and Firhealth (Firhealth, Shenzhen, China)] were compared with an electronic axillary thermometer and an infrared tympanic thermometer. Main outcome measures The primary outcome was agreement between the Thermofocus non-contact infrared thermometer and the axillary thermometer. Secondary outcomes included agreement between all other sets of thermometers, diagnostic accuracy for detecting fever, parental and child ratings of acceptability and discomfort, and themes arising from our qualitative interviews with parents. Results A total of 401 children (203 boys) were recruited, with a median age of 1.6 years (interquartile range 0.79–3.38 years). The readings of the Thermofocus non-contact infrared thermometer differed from those of the axillary thermometer by –0.14 °C (95% confidence interval –0.21 to –0.06 °C) on average with the lower limit of agreement being –1.57 °C (95% confidence interval –1.69 to –1.44 °C) and the upper limit being 1.29 °C (95% confidence interval 1.16 to 1.42 °C). The readings of the Firhealth non-contact infrared thermometer differed from those of the axillary thermometer by –0.16 °C (95% confidence interval –0.23 to –0.09 °C) on average, with the lower limit of agreement being –1.54 °C (95% confidence interval –1.66 to –1.41 °C) and the upper limit being 1.22 °C (95% confidence interval 1.10 to 1.34 °C). The difference between the first and second readings of the Thermofocus was –0.04 °C (95% confidence interval –0.07 to –0.01 °C); the lower limit was –0.56 °C (95% confidence interval –0.60 to –0.51 °C) and the upper limit was 0.47 °C (95% confidence interval 0.43 to 0.52 °C). The difference between the first and second readings of the Firhealth thermometer was 0.01 °C (95% confidence interval –0.02 to 0.04 °C); the lower limit was –0.60 °C (95% confidence interval –0.65 to –0.54 °C) and the upper limit was 0.61 °C (95% confidence interval 0.56 to 0.67 °C). Sensitivity and specificity for the Thermofocus non-contact infrared thermometer were 66.7% (95% confidence interval 38.4% to 88.2%) and 98.0% (95% confidence interval 96.0% to 99.2%), respectively. For the Firhealth non-contact infrared thermometer, sensitivity was 12.5% (95% confidence interval 1.6% to 38.3%) and specificity was 99.4% (95% confidence interval 98.0% to 99.9%). The majority of parents found all methods to be acceptable, although discomfort ratings were highest for the axillary thermometer. The non-contact thermometers required fewer readings than the comparator thermometers. Limitations A method comparison study does not compare new methods against a reference standard, which in this case would be central thermometry requiring the placement of a central line, which is not feasible or acceptable in primary care. Electronic axillary and infrared tympanic thermometers have been found to have moderate agreement themselves with central temperature measurements. Conclusions The 95% limits of agreement are > 1 °C for both non-contact infrared thermometers compared with electronic axillary and infrared tympanic thermometers, which could affect clinical decision-making. Sensitivity for fever was low to moderate for both non-contact thermometers. Future work Better methods for peripheral temperature measurement that agree well with central thermometry are needed. Trial registration Current Controlled Trials ISRCTN15413321. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 24, No. 53. See the NIHR Journals Library website for further project information.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
忧郁小鸽子完成签到,获得积分10
9秒前
科研通AI5应助科研通管家采纳,获得10
23秒前
小马甲应助budingman采纳,获得10
36秒前
小二郎应助budingman采纳,获得10
36秒前
顾矜应助budingman采纳,获得10
36秒前
共享精神应助budingman采纳,获得10
37秒前
深情安青应助budingman采纳,获得10
37秒前
CipherSage应助budingman采纳,获得10
37秒前
44秒前
柔弱烨霖发布了新的文献求助10
49秒前
1分钟前
852应助budingman采纳,获得10
1分钟前
领导范儿应助budingman采纳,获得10
1分钟前
香蕉觅云应助budingman采纳,获得10
1分钟前
汉堡包应助budingman采纳,获得10
1分钟前
Owen应助budingman采纳,获得10
1分钟前
1分钟前
传奇3应助budingman采纳,获得10
1分钟前
Orange应助budingman采纳,获得10
1分钟前
Lucas应助budingman采纳,获得10
1分钟前
科研通AI5应助budingman采纳,获得10
1分钟前
江流有声发布了新的文献求助10
1分钟前
CodeCraft应助铉莉采纳,获得10
1分钟前
mashibeo完成签到,获得积分10
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
1分钟前
高分求助中
Technologies supporting mass customization of apparel: A pilot project 600
Introduction to Strong Mixing Conditions Volumes 1-3 500
Tip60 complex regulates eggshell formation and oviposition in the white-backed planthopper, providing effective targets for pest control 400
A Field Guide to the Amphibians and Reptiles of Madagascar - Frank Glaw and Miguel Vences - 3rd Edition 400
China Gadabouts: New Frontiers of Humanitarian Nursing, 1941–51 400
The Healthy Socialist Life in Maoist China, 1949–1980 400
Walking a Tightrope: Memories of Wu Jieping, Personal Physician to China's Leaders 400
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 物理 生物化学 纳米技术 计算机科学 化学工程 内科学 复合材料 物理化学 电极 遗传学 量子力学 基因 冶金 催化作用
热门帖子
关注 科研通微信公众号,转发送积分 3798503
求助须知:如何正确求助?哪些是违规求助? 3343971
关于积分的说明 10318265
捐赠科研通 3060565
什么是DOI,文献DOI怎么找? 1679670
邀请新用户注册赠送积分活动 806731
科研通“疑难数据库(出版商)”最低求助积分说明 763323