医学
踝关节置换术
脚踝
前瞻性队列研究
涂层
外科
单中心
存活率
牙科
复合材料
材料科学
作者
Kristian K. Nielsen,N C Jensen,Frank Linde
标识
DOI:10.1016/j.fas.2023.09.003
摘要
Different coatings of the metal implants of STAR prostheses have been used since 1999. In Europe metal implants with a double calcium-phosphate coating (BONIT) on a titanium sprayed surface have been available since 1999.We present a 2-17 year follow-up of a consecutive series from a single center with 474 STAR ankle replacements where the BONIT type of coating has been used.55 prostheses (12%) have been revised, the majority of them due to fracture of the mobile bearing. 22 prostheses (5%) have been converted to an arthrodesis. Analysis of survival of the specific components showed an estimated 10-year survival rate of the tibia component, talus component and polyethylene mobile bearing of 99%, 98% and 84%, respectively. The corresponding estimated 15-year survival was 98%, 98% and 74%, respectively.This study showed an extraordinary high survival rate of the metal implants.Level III, prospective cohort series.
科研通智能强力驱动
Strongly Powered by AbleSci AI